    A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.</p> <p>Methods</p> <p>A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made.</p> <p>Results</p> <p>The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures.</p> <p>Conclusions</p> <p>The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.</p

    Manufacturing conditioned wear of all-ceramic knee prostheses

    Get PDF
    To date, bioceramics have not been applied successfully in total knee joint endoprostheses. Sintered bioceramics can be machined only by grinding and polishing processes. Due to high quality requirements, there are significant challenges with regard to these machining technologies. An automated precise economical process chain for the manufacturing of a new all-ceramic knee implant design was developed. It was assumed the geometrical accuracy and the shape of implant contact geometry specified during the manufacturing process has a substantial influence on the wear behavior of the prosthesis. The importance of the surface quality of the ceramic implant surface remains unclear and warrants future examination

    Influence of stress on the degradation behavior of Mg LAE442 implant systems

    Get PDF
    In this paper the performance of a magnesium based implant system is analyzed. A special emphasis is placed on the impact of stress on the corrosion behavior of the magnesium alloy. An implant system containing a plate and 4 corresponding screws is machined from Mg LAE442. Its corrosion behavior is tested in-vivo in New Zealand White Rabbits for 6 and 12 weeks of implantation. The plate is monocortically fixated on the medial tibia. At the interface between screw and plate increased corrosion is observed. This phenomenon is stronger on the caudal side of the screw. Parallel to the in-vivo test the influence of stress load on the corrosion rate is analyzed for LAE442 in in-vitro tests. Compressive load is applied on cylindrical specimens in axial direction and the corrosion rate is measured in 0.9 wt% NaCl solution by eudiometry and mass loss. Additionally rectangular samples are bent to apply tensile stress on the surface. A drop of 5 wt% NaCl is deposited on the surface and the corrosion is evaluated by microscopic images. It is shown that stress essentially influences the corrosion rate. While tensile stress decreases the corrosion, compressive stress leads to higher corrosion rates

    Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants

    Get PDF
    Background: Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods: A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results: The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions: It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.DFG/CRC/59